Filter: ladspa.5002118

Plugin Information

title: Sidechain Gate Mono
media types: Audio
description: LADSPA plugin
version: 3
creator: LSP LADSPA
license: GPLv2
URL: http://www.ladspa.org/

Notes

Automatically adapts to the number of channels and sampling rate of the consumer.

Bugs

  • Some effects have a temporal side-effect that may not work well.

Parameters

3

title: Bypass
type: boolean
readonly: no
required: no
animation: yes
minimum: 0
default: 0

4

title: Input gain (G)
description: logarithmic scale recommended
type: float
readonly: no
required: no
animation: yes
minimum: 1.19209e-07
maximum: 1000
default: 1

5

title: Output gain (G)
description: logarithmic scale recommended
type: float
readonly: no
required: no
animation: yes
minimum: 1.19209e-07
maximum: 1000
default: 1

6

title: Pause graph analysis
type: boolean
readonly: no
required: no
animation: yes
minimum: 0
default: 0

7

title: Clear graph analysis
type: boolean
readonly: no
required: no
animation: yes
minimum: 0
default: 0

8

title: Sidechain input
type: integer
readonly: no
required: no
animation: yes
minimum: 0
maximum: 1
default: 0

9

title: Sidechain mode
type: integer
readonly: no
required: no
animation: yes
minimum: 0
maximum: 3
default: 1

10

title: Sidechain lookahead (ms)
type: float
readonly: no
required: no
animation: yes
minimum: 0
maximum: 20
default: 0

11

title: Sidechain listen
type: boolean
readonly: no
required: no
animation: yes
minimum: 0
default: 0

12

title: Sidechain reactivity (ms)
description: logarithmic scale recommended
type: float
readonly: no
required: no
animation: yes
minimum: 1.19209e-07
maximum: 250
default: 0.00545915

13

title: Sidechain preamp (G)
description: logarithmic scale recommended
type: float
readonly: no
required: no
animation: yes
minimum: 1.19209e-07
maximum: 100
default: 1

14

title: High-pass filter mode
type: integer
readonly: no
required: no
animation: yes
minimum: 0
maximum: 3
default: 0

15

title: High-pass filter frequency (Hz)
description: logarithmic scale recommended
type: float
readonly: no
required: no
animation: yes
minimum: 10
maximum: 20000
default: 10

16

title: Low-pass filter mode
type: integer
readonly: no
required: no
animation: yes
minimum: 0
maximum: 3
default: 0

17

title: Low-pass filter frequency (Hz)
description: logarithmic scale recommended
type: float
readonly: no
required: no
animation: yes
minimum: 10
maximum: 20000
default: 20000

18

title: Hysteresis
type: boolean
readonly: no
required: no
animation: yes
minimum: 0
default: 0

19

title: Curve threshold (G)
description: logarithmic scale recommended
type: float
readonly: no
required: no
animation: yes
minimum: 0.001
maximum: 1
default: 0.0316228

20

title: Curve zone size (G)
description: logarithmic scale recommended
type: float
readonly: no
required: no
animation: yes
minimum: 0.001
maximum: 1
default: 0.177828

21

title: Hysteresis threshold (G)
description: logarithmic scale recommended
type: float
readonly: no
required: no
animation: yes
minimum: 0.001
maximum: 1
default: 0.177828

22

title: Hysteresis zone size (G)
description: logarithmic scale recommended
type: float
readonly: no
required: no
animation: yes
minimum: 0.001
maximum: 1
default: 0.177828

23

title: Attack (ms)
description: logarithmic scale recommended
type: float
readonly: no
required: no
animation: yes
minimum: 1.19209e-07
maximum: 2000
default: 0.0154408

24

title: Release (ms)
description: logarithmic scale recommended
type: float
readonly: no
required: no
animation: yes
minimum: 1.19209e-07
maximum: 5000
default: 100

25

title: Reduction (G)
description: logarithmic scale recommended
type: float
readonly: no
required: no
animation: yes
minimum: 0.00025119
maximum: 3981.07
default: 1

26

title: Makeup gain (G)
description: logarithmic scale recommended
type: float
readonly: no
required: no
animation: yes
minimum: 0.001
maximum: 1000
default: 1

27

title: Dry gain (G)
description: logarithmic scale recommended
type: float
readonly: no
required: no
animation: yes
minimum: 1.19209e-07
maximum: 10
default: 0

28

title: Wet gain (G)
description: logarithmic scale recommended
type: float
readonly: no
required: no
animation: yes
minimum: 1.19209e-07
maximum: 10
default: 1

32

title: Sidechain level visibility
type: boolean
readonly: no
required: no
animation: yes
minimum: 0
default: 1

33

title: Envelope level visibility
type: boolean
readonly: no
required: no
animation: yes
minimum: 0
default: 1

34

title: Gain reduction visibility
type: boolean
readonly: no
required: no
animation: yes
minimum: 0
default: 1

35

title: Input level visibility
type: boolean
readonly: no
required: no
animation: yes
minimum: 0
default: 1

36

title: Output level visibility
type: boolean
readonly: no
required: no
animation: yes
minimum: 0
default: 1

29[*]

title: Zone start (G)
description: logarithmic scale recommended
type: float
readonly: yes
required: no
animation: yes
minimum: 1.19209e-07
maximum: 15.8489
default: 0

30[*]

title: Hysteresis threshold start (G)
description: logarithmic scale recommended
type: float
readonly: yes
required: no
animation: yes
minimum: 1.19209e-07
maximum: 15.8489
default: 0

31[*]

title: Hysteresis zone start (G)
description: logarithmic scale recommended
type: float
readonly: yes
required: no
animation: yes
minimum: 1.19209e-07
maximum: 15.8489
default: 0

37[*]

title: Sidechain level meter (G)
description: logarithmic scale recommended
type: float
readonly: yes
required: no
animation: yes
minimum: 1.19209e-07
maximum: 15.8489
default: 0

38[*]

title: Curve level meter (G)
description: logarithmic scale recommended
type: float
readonly: yes
required: no
animation: yes
minimum: 1.19209e-07
maximum: 15.8489
default: 0

39[*]

title: Envelope level meter (G)
description: logarithmic scale recommended
type: float
readonly: yes
required: no
animation: yes
minimum: 1.19209e-07
maximum: 15.8489
default: 0

40[*]

title: Reduction level meter (G)
description: logarithmic scale recommended
type: float
readonly: yes
required: no
animation: yes
minimum: 1.19209e-07
maximum: 1
default: 0

41[*]

title: Input level meter (G)
description: logarithmic scale recommended
type: float
readonly: yes
required: no
animation: yes
minimum: 1.19209e-07
maximum: 15.8489
default: 0

42[*]

title: Output level meter (G)
description: logarithmic scale recommended
type: float
readonly: yes
required: no
animation: yes
minimum: 1.19209e-07
maximum: 15.8489
default: 0

43[*]

title: latency
type: integer
readonly: yes
required: no
animation: yes
minimum: 0
default: 0

instances

title: Instances
description:

The number of instances of the plugin that are in use.
MLT will create the number of plugins that are required to support the number of audio channels.
Status parameters (readonly) are provided for each instance and are accessed by specifying the instance number after the identifier (starting at zero).
e.g. 9[0] provides the value of status 9 for the first instance.

type: integer
readonly: yes
required: no

wetness

title: Wet/Dry
type: float
readonly: no
required: no
animation: yes
minimum: 0
maximum: 1
default: 1

channel_mask

title: Channel Mask
description: A bitmask indicating which channels to affect.
type: integer
readonly: no
required: no
minimum: 0
default: 4294967295

Search

Subscribe

Subscribe to News via RSS.

Recent Posts

About

MLT enables you to author, manage, and run multitrack audio/video compositions. Copyright © 2008-2026 by Meltytech, LLC.

Social Links